High Current Power Supply (HCDPS) 6 Device PowerSupply
System Reference, January 2001
173
e. Over-current Protection
There are two modes to be considered here:
I) Constant current mode: When the current limit is
reached, the HCDPS operates as a constant current
source. Note: Constant current mode is not possible
in ganged mode.
II) Clamp mode: When the current limit is reached,
the DPS switches to tristate.
For these modes, three different delay times (2ms,
6ms, and 8ms) can be programmed using the firm-
ware command HSCM (for details of this command
see the section, “Firmware Commands for the
HCDPS” on page 178 or the Command Reference
manual).
Note: When the DPS switches to tristate because of
having reached current limit, it does not pull down
the safety line
4. Balancing Circuits.
The 12 phase stepdown converter is organized in 6
pairs, phase-shifted by 180° to each other. Each pair
has its own shunt resistor to measure its output
current. All 6 current measurements are summed up
to a mean value. Regulators compare the mean value
with each of the 6 single currents and balance them to
be equal. If the current of one stage rises so much that
the balancing is never possible, a failure signal is
generated which:
a. Switches the HCDPS to tristate.
b. Creates a flag to be read by the software.
c. Switches also all HCPS to tristate which are
connected to the same safety_line.