7 Analog Modules Synchronization
242 System Reference, January 2001
Synchronization
This section provides the following information for
synchronizing between the digital channel operation and
the analog module operation (except for TIA):
Synchronization concepts
Technical data of the synchronization trigger
How to adjust the synchronization timing
How to remove the synchronization
uncertainty that
occurs in the high speed analog module
s
Special synchronization function for high speed AWGs
and dual high speed samplers
Synchronization Concepts
An analog module starts the operation when it receives a
trigger signal. The trigger signal for the analog module is
provided by a digital channel generally. All analog
modules have dedicated trigger input pins. For sending
the trigger signal, you have to connect the digital pin that
provides the trigger signal and the trigger input pin of the
analog module on the DUT board.
Trigger-to-Delay and
Uncertainty
Analog modules start measurement or waveform genera-
tion after a certain delay from the time the trigger signal is
received. This delay time is called trigger-to-signal delay.
Each analog module has a dedicated value of delay time.
The analog module’s timing calibration supported by the
system compensates the trigger-to-signal delay in each
analog module. After the calibration, the trigger-to-signal
delay will become the fixed value for each analog module.
The following table shows the fixed value of the trigger-to-
signal delay, the accuracy of the trigger-to-signal delay,
and uncertainty of the analog module’s start timing.